After reading a little about the Mppt controllers I understand that excess voltage is turned into current at the controller. But dose that also give me the ability to run my panels in series creating 40 or 60 volts and then having the volts converted to amps for 12 volt system at the controller. If so is there a downside to doing so? the obvious up side being running a lighter wire size and less loss of power in wiring.
Try our solar cost and savings calculator
Most Popular Topics
Collapse
MPPT controllers
Collapse
X
-
-
You nailed it ! go to the head of the class.Powerfab top of pole PV mount (2) | Listeroid 6/1 w/st5 gen head | XW6048 inverter/chgr | Iota 48V/15A charger | Morningstar 60A MPPT | 48V, 800A NiFe Battery (in series)| 15, Evergreen 205w "12V" PV array on pole | Midnight ePanel | Grundfos 10 SO5-9 with 3 wire Franklin Electric motor (1/2hp 240V 1ph ) on a timer for 3 hr noontime run - Runs off PV ||
|| Midnight Classic 200 | 10, Evergreen 200w in a 160VOC array ||
|| VEC1093 12V Charger | Maha C401 aa/aaa Charger | SureSine | Sunsaver MPPT 15A
solar: http://tinyurl.com/LMR-Solar
gen: http://tinyurl.com/LMR-Lister -
Comment
-
I have question about MPPT controllers that most of them they take up to 40v. 12v solar panel have open voltage of 21.6. when connecting 2 panels in series will produce 43.3v. Will that damage the controller in any way will that affect charging 12 battery under full sun?Comment
-
Comment
-
Best to follow the directions the mfg gives, if they say 40V, and you fry the controller with 43.3V, then it likely won't charge the battery anymore.
There are some good , small amp controllers, Morningstar 15A MPPT, Rogue MPPT, Blue Sky MPPT that have varied input voltages. When you get to the higher amp controllers, 45, 60, 80A, then you have higher voltage DC inputs.Powerfab top of pole PV mount (2) | Listeroid 6/1 w/st5 gen head | XW6048 inverter/chgr | Iota 48V/15A charger | Morningstar 60A MPPT | 48V, 800A NiFe Battery (in series)| 15, Evergreen 205w "12V" PV array on pole | Midnight ePanel | Grundfos 10 SO5-9 with 3 wire Franklin Electric motor (1/2hp 240V 1ph ) on a timer for 3 hr noontime run - Runs off PV ||
|| Midnight Classic 200 | 10, Evergreen 200w in a 160VOC array ||
|| VEC1093 12V Charger | Maha C401 aa/aaa Charger | SureSine | Sunsaver MPPT 15A
solar: http://tinyurl.com/LMR-Solar
gen: http://tinyurl.com/LMR-ListerComment
Copyright © 2014 SolarReviews All rights reserved.
Powered by vBulletin® Version 6.1.3
Copyright © 2026 MH Sub I, LLC dba vBulletin. All rights reserved.
Copyright © 2026 MH Sub I, LLC dba vBulletin. All rights reserved.
All times are GMT-5. This page was generated at 07:46 AM.
Comment